Section 1 - Product and Company Information

Product Name: Flexible Spot Putty
Product Part Number(s): 1040-T

COMPANY IDENTIFICATION:EMERGENCY TELEPHONE NUMBER
Urethane Supply Company24 Hour Emergency ContactChemtrec - 1-800-424-9300
1128 Kirk Rd.Customer Information Number256-638-4103
Rainsville, AL 35986

Section 2 - Hazards Identification

Appearance:Pink Putty
Odor:Strong
Hazards of Product:
  

HMIS Rating (Scale 0 - 4)

NFPA Ratings
HEALTH  2  Health = 2
 2 
2 0
Health = 2
FIRE  2  Fire = 2Fire = 2
PHYSICAL  1  Physical = 1Reactivity = 0
PERSONAL PROTECTIONGPersonal Protection = G 


Potential Health Effects

Eye Contact:Moderate irritation, redness, blurred vision.
Skin Absorption:Moderate irritation, redness, dermatitis
 
Inhalation:Nasal and respiratory irritation, dizziness, headache, nausea, possible unconsciousness, and asphyxiation.
 
Ingestion:Gastrointestinal irritation, vomiting, diarrhea
 

Section 3 - Composition/Information on Ingredients

ComponentCAS #Amount
 
Methyl Ethyl Ketone78-93-33-5%
Isobutyl Acetate110-19-05-6%
Aliphatic Petroleum Naphthas64742-89-84-5%
Isobutyl Isobutyrate97-85-8NA
Toluene108-88-32-3%
Xylene1330-20-7<1%
Ethyl Benzene100-41-4<1%
Ethylene Glycol Monobutyl Ether111-16-2<1%

Section 4 - First-Aid Measures

Medical Conditions Aggravated by Exposure: Bronchitis, CNS disorders, allergies, nausea.
 

Section 5 - Fire Fighting Measures

Extinguishing Media: Foam, Alcohol, CO2, Dry Chemical
 
Fire Fighting Procedures: Water spray may be ineffective, but may be used to cool containers exposed to heat. Wear self-contained breathing apparatus.
 
Unusual Fire and Explosion Hazards: Vapors may ignite explosively. Exposure to heat or prolonged exposure to sun may cause bursting. Do not expose to heat or store at temperatures above 120 F. Do not puncture or incinerate container.
 

Section 6 - Accidental Release Measures

Steps to be Taken if Material is Released or Spilled: Remove all sources of ignition. Allow volatile portion to evaporate completely. Avoid breathing vapors and remove with inert absorbent.
 
Personal Precautions:
 
Environmental Precautions:
 

Section 7 - Handling and Storage

General Handling: Reports have associated repeated and prolonged occupational overexposure to solvents with permanent brain and nervous system damage. Intentional misuse by deliberately concentrating and inhaling the contents may be harmful or fatal. Avoid spontaneouscombustion of contaminated rags or other ignitable material. Keep out of reach of children.
 
Other Precautions:
 
Storage: Do no store near heat sparks or flame. Store in well ventilated area. Keep closure tight and container upright to prevent leakage. Do not puncture or incinerate.
 

Section 8 - Exposure Controls / Personal Protection

ComponentSourceTypeValueRemarks
Aliphatic Petroleum NaphthasACGIHTLV300 ppmTWA
Aliphatic Petroleum NaphthasOSHAPEL300 ppmTWA
Aliphatic Petroleum NaphthasOSHAPEL400 ppmSTEL
Isobutyl AcetateACGIHTLV150 ppmTWA
Isobutyl AcetateOSHAPEL150 ppmTWA
Methyl Ethyl KetoneACGIHTLV300 ppmSTEL
Methyl Ethyl KetoneOSHAPEL300 ppmSTEL
Methyl Ethyl KetoneOSHAPEL200 ppmTWA
Methyl Ethyl KetoneACGIHTLV200 ppmTWA
TolueneACGIHTLV20 ppmTWA
TolueneOSHACeiling300 ppm
TolueneOSHAPEL150 ppmSTEL
TolueneOSHAPEL100 ppmTWA
XyleneOSHAPEL150 ppmSTEL
XyleneACGIHTLV100 ppmTWA
XyleneACGIHTLV150 ppmSTEL
XyleneOSHAPEL100 ppmTWA
Personal Protection
Eye/Face Protection: Goggles or side-shielded safety glasses.
 
Skin Protection: Neoprene or butyl rubber gloves.
 
Respiratory Protection: Use of a NIOSH approved chemical/mechanical filter, designed to remove a combination of particles and vapors.
 
Hygenic Measures: Wash hands before eating, smoking or using the washroom.
 
Other Protection Measures: To prevent repeated or prolonged skin contact, wear impervious clothing and boots. Wash contaminated clothing before reuse.
 
Engineering Controls: Provide sufficient mechanical (general and/or local exhaust) ventilation to maintain exposure below TLV(s)
 

Section 9 - Physical and Chemical Properties

Appearance: Pink Paste
 
Color: Pink
 
Flash Point: 23F
 
Upper Flammable Limit: 11.5
 
Lower Flammable Limit: 0.9
 
Boiling Point: 175.0
 
Vapor Density: Heavier than air
 
Specific Gravity: 1.40
 
Solubility in Water: Stable
 

Section 10 - Stability and Reactivity

Stability/Instability: Stable
 
Conditions To Avoid: Excessive heat, open flames, spark sources
 
Incompatible Materials: Oxidizing agents
 
Hazardous Polymerization: Will Not Occur
 
Hazardous Decomposition Products: Carbon monoxide, carbon dioxide, various hydrocarbons, oxides of nitrogen.
 

Section 11 - Toxicological Information

Acute Toxicity
Ingestion

<1%
Skin Absorption
<1%
Inhalation
<1%
 

Section 12 - Ecological Information

CHEMICAL FATE

Section 13 - Disposal Considerations

Disposal Method:
Do not incinerate. Dispose of in accordance with local, state and federal regulations. Do not contaminate lakes, streams, or other water supply.
 
Container Disposal: Disposal must be made according to official regulations.
 

Section 14 - Transport Information

DOT

Proper Shipping Name: Adhesive, containing a flammable liquid
 
Hazard Class: 3
 
ID Number: UN1133
 
Packing Group: II
 

Maritime transport IMDG

IMDG Class: 3
UN Number: UN1133
Label: Flamm. Liquid
Packaging Group: II
EMS Number: F-E, S-D
Maritime Marine Pollutant: No
Proper Shipping Name: ADHESIVE, containing flammable liquid

Air Transport ICAO-TI and IATA-DGR

ICAO/IATA Class: 3
UN/ID Number: UN1133
Label: Flamm. Liquid
Air Packaging Group: II
Proper Shipping Name: Adhesive, containing flammable liquid

Section 15 - Regulatory Information

Superfund Amendments and Reathorization Act of 1986 (Emergency Planning and Community Right-to-Know Act of 1986) Sections 311 and 312

The following table list hazardous components and the regulatory lists for which they are required to be reported.
Component CAS # Amount SARA 313 Listed Known to California to cause cancer Pennsylvania Hazardous Substance List Massachusetts Hazardous Listed Rhode Island Listed CERCLA EPA Cancer ogenicity IARC Cancer ogenicity NTP Cancerc ogenicity TLV Cancer ogenicity NIOSH Cancer ogenicity OSHA Cancer ogenicity
Xylene 1330-20-7 <1%            

Section 16 - Other Information

Legend
ACGIHAmerican Conference of Governmental Hygenists
CFRCode of Federal Regulations
DFGDeutsche Forschungsgemeinschaft
HMISHazardous Materials Identification System
IARCInternational Agency for Research on Cancer
MAKMaximum Allowable Concentration (German)
MSDSMaterial Safety Data Sheet
NFPANational Fire Protection Association
NIOSHNational Institute for Occupational Safety and Health
OELOccupational Exposure Limit
RCRAResource Conservation and Recovery Act
STELShort Term Exposure Limit
TLVThreshold Limit Value
TWATime Weighted Average

This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship.